歡迎訪問中科光析科學(xué)技術(shù)研究所官網(wǎng)!
免費(fèi)咨詢熱線
400-635-0567
管道和排水用銅合金管檢測項(xiàng)目報(bào)價(jià)???解決方案???檢測周期???樣品要求? |
點(diǎn) 擊 解 答??![]() |
本規(guī)程規(guī)定了工業(yè)氧氣及相關(guān)氣體的生產(chǎn)(含設(shè)計(jì)、制造、安裝、改造、維修)、儲存、輸配和使用中應(yīng)遵守的要求。本規(guī)程適用于新建、擴(kuò)建和改建的采用深度冷凍法生產(chǎn)氧氣及相關(guān)氣體的單位。
本部分適用于船舶、固定或漂浮式海上結(jié)構(gòu)物和內(nèi)河船舶上生活用水供應(yīng)系統(tǒng)的規(guī)劃、設(shè)計(jì)和布置。 本部分規(guī)定了為保護(hù)生活用水和維持水質(zhì)所需的生活用水供應(yīng)系統(tǒng)低要求,并提供了部件使用和管道布置的相關(guān)信息。 本部分不涉及生活用水輸送的相關(guān)規(guī)則,生活用水的輸送應(yīng)遵守專門規(guī)定。
本標(biāo)準(zhǔn)給出了石油和天然氣工業(yè)海上生產(chǎn)平臺新建管道系統(tǒng)的設(shè)計(jì)和安裝的低要求和指南。管道系統(tǒng)的高壓力高達(dá)69000kPa(G),在溫度范圍內(nèi)對材料的要求滿足ASME B31.3的要求。
本標(biāo)準(zhǔn)規(guī)定了燃?xì)膺^濾器產(chǎn)品的分類、代號和型號,結(jié)構(gòu)和材料,要求,試驗(yàn)方法,檢驗(yàn)規(guī)則及質(zhì)量證明文件、標(biāo)志、包裝、運(yùn)輸和貯存。本標(biāo)準(zhǔn)適用于公稱壓力不大于10.0 MPa、公稱尺寸不大于600 mm、工作溫度范圍為-20 ℃~60 ℃燃?xì)廨斉湎到y(tǒng)中的燃?xì)膺^濾器。本標(biāo)準(zhǔn)不適用于石油和(或)天然氣生產(chǎn)過程中的氣液分離器。
本規(guī)范適用于設(shè)計(jì)壓力不大于42MPa,設(shè)計(jì)溫度不超過材料允許使用溫度的工業(yè)金屬管道工程的施工。本規(guī)范不適用于下列工業(yè)金屬管道的施工:1 石油、天然氣、地?zé)岬瓤碧胶筒删蜓b置的管道;2 長輸管道;3 核能裝置的專用管道;4 海上設(shè)施和礦井的管道;5 采暖通風(fēng)與空氣調(diào)節(jié)的管道及非圓形截面的管道。
本規(guī)范適用于火力發(fā)電廠及核能發(fā)電廠的反滲透法和蒸餾法海水淡化系統(tǒng)設(shè)計(jì)。
本規(guī)范適用于有色金屬加工企業(yè)銅、鋁加工項(xiàng)目新建、改建和擴(kuò)建工程的節(jié)能設(shè)計(jì)。
本規(guī)范適用于銅、鋁、鉛、鎳、鈦、鋯、鉭、鈮及其合金的工業(yè)管道工程的施工及質(zhì)量驗(yàn)收。本規(guī)范不適用于下列工業(yè)有色金屬管道工程的施工及質(zhì)量驗(yàn)收:1 制造廠成套設(shè)計(jì)整裝于設(shè)備的管道。2 軍用設(shè)施及核能裝置的專用管道。3 海上設(shè)施和礦井用管道。
本標(biāo)準(zhǔn)規(guī)定了法蘭連接尺寸按JIS B2240-1996的J類外卡式消防接頭(以下簡稱接頭)的分類、要求、試驗(yàn)方法、檢驗(yàn)規(guī)則、標(biāo)志和包裝。 本標(biāo)準(zhǔn)適用于船舶水消防管路系統(tǒng)用接頭的設(shè)計(jì)、制造和驗(yàn)收。
本規(guī)程適用于新建、改建和擴(kuò)建的建筑給水(包括生活熱水、飲用凈水等)銅管管道工程的設(shè)計(jì)、施工及驗(yàn)收。
為統(tǒng)一城鎮(zhèn)燃?xì)馐覂?nèi)工程的施工與質(zhì)量驗(yàn)收,保證城鎮(zhèn)燃?xì)馐覂?nèi)工程的施工質(zhì)量,確保安全供氣,制定本規(guī)范。本規(guī)范適用于供氣壓小于或等于0.8MPa(表壓)的新建、擴(kuò)建和改建的城鎮(zhèn)居民住宅、商業(yè)用戶、燃?xì)忮仩t房(不含鍋爐本體)、實(shí)驗(yàn)室、工業(yè)企業(yè)(不含用氣設(shè)備)等用戶室內(nèi)燃?xì)夤艿篮陀脷庠O(shè)備安裝的施工與質(zhì)量驗(yàn)收。
本標(biāo)準(zhǔn)適用于有色金屬工業(yè)通用設(shè)備安裝工程質(zhì)量的檢驗(yàn)評定。本標(biāo)準(zhǔn)應(yīng)與現(xiàn)行行業(yè)標(biāo)準(zhǔn)《有色金屬工業(yè)安裝工程質(zhì)量檢驗(yàn)評定統(tǒng)一標(biāo)準(zhǔn)》YS/T 5419配合使用。
1.1 This specification establishes the requirements for seamless copper tube (DWV) produced from Copper UNS No. C12200 and intended for sanitary drainage, waste, and vent piping. Note 18212;Fittings used for soldered or brazed connections in drainage, waste, or vent systems are described in ASME Standards B16.23 and B16.29 and CSA Standard B158.1. Note 28212;The assembly of copper drainage, waste, and vent systems by soldering is described in Practice B 828.Note 38212;Solders for joining copper drainage, waste, or vent systems are described in Specification B 32. The requirement for acceptable fluxes for these systems are described in Specification B 813.1.2 Values stated in inch-pound units are the standard. SI values given in parentheses are for information only.1.3 The following hazard statement pertains only to the test method described in Section 16.2.3 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
17.1x00a0;For the purpose of determining compliance with the specified limits for requirements of the properties listed in the following table, an observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice E29: Property Rounded Unit for Observed or Calculated Value x00a0; 8199;8199;8199;Chemical composition nearest unit in the last right-hand place of 8199;8199;8199;Hardness 8199;figures of the specified limit x00a0; x00a0; 8199;8199;8199;Tensile strength nearest ksi (5 MPa) 1.1x00a0;This specification establishes the requirements for seamless copper tube (DWV) produced from Copper UNS No. C12200 and intended for sanitary drainage, waste, and vent piping. Note 1x2014;Fittings used for soldered or brazed connections in drainage, waste, or vent systems are described in ASME Standards B16.23 and B16.29 and CSA Standard B158.1. Note 2x2014;The assembly of copper drainage, waste, and vent systems by soldering is described in Practice B828. Note 3x2014;Solders for joining copper drainage, waste, or vent systems are described in Specification B32. The requirement for acceptable fluxes for these systems are described in Specification B813. 1.2x00a0;The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This classification is provided to serve the needs of designers, specifiers, installers, and users of seamless copper and copper alloy plumbing tube and piping systems. It familiarizes them with the products available for such systems, giving size ranges and available materials for products listed herein. Also refer to Section 1.1.1 This classification covers various types of seamless copper and copper alloy pipe and tube used for water service, distribution, and drainage. It is not a specification for the various types and alloys.1.2 This classification uses the standard copper designations developed and used by the copper industry.1.3 This classification makes no attempt to differentiate between all compositions that could be termed coppers or copper alloys, but, in conformance with general practice in the trade includes those coppers and copper alloys commonly used in the manufacture of water service, distribution, and drainage pipe and tube.1.4 This classification makes no attempt to differentiate between all applications of seamless copper and copper alloy piping and tubing, and is intended for use in water service distribution and drainage.
This classification is provided to serve the needs of designers, specifiers, installers, and users of seamless copper and copper alloy plumbing tube and piping systems. It familiarizes them with the products available for such systems, giving size ranges and available materials for products listed herein. Also refer to Section 1.1.1 This classification covers various types of seamless copper and copper alloy pipe and tube used for water service, distribution, and drainage. It is not a specification for the various types and alloys. 1.2 This classification uses the standard copper designations developed and used by the copper industry. 1.3 This classification makes no attempt to differentiate between all compositions that could be termed coppers or copper alloys, but, in conformance with general practice in the trade includes those coppers and copper alloys commonly used in the manufacture of water service, distribution, and drainage pipe and tube. 1.4 This classification makes no attempt to differentiate between all applications of seamless copper and copper alloy piping and tube intended for use in water service distribution and drainage.
4.1x00a0;This classification is provided to serve the needs of designers, specifiers, installers, and users of seamless copper and copper alloy plumbing tube and piping systems. It familiarizes them with the products available for such systems, giving size ranges and available materials for products listed herein. Also refer to Section 1. 1.1x00a0;This classification covers various types of seamless copper and copper alloy2 pipe and tube used for water service, distribution, and drainage. It is not a specification for the various types and alloys. 1.2x00a0;This classification uses the standard copper designations developed and used by the copper industry. 1.3x00a0;This classification makes no attempt to differentiate between all compositions that could be termed coppers or copper alloys, but, in conformance with general practice in the trade, includes those coppers and copper alloys commonly used in the manufacture of water service, distribution, and drainage pipe and tube. 1.4x00a0;This classification makes no attempt to differentiate between all applications of seamless copper and copper alloy piping and tube intended for use in water service distribution and drainage. 1.5x00a0;The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
The techniques described herein are used to produce leak-tight soldered joints between copper and copper alloy tube and fittings, either in shop operations or in the field. Skill and knowledge on the part of the operator or mechanic are required to obtain a satisfactorily soldered joint. 1.1 This practice describes a procedure for making capillary joints by soldering of copper and copper alloy tube and fittings. 1.2 This procedure is applicable to pressurized systems such as plumbing, heating, air conditioning, refrigeration, mechanical, fire sprinkler, and other similar systems. ASME B31.5 and B31.9 reference the techniques used for satisfactory joint preparation. It is also used in the assembly of nonpressurized systems such as drainage, waste, and vent. 1.3 It is not applicable to the assembly of electrical or electronic systems. 1.4 Tube and fittings are manufactured within certain tolerances to provide for the small variations in dimensions associated with manufacturing practice. Applicable specifications are listed in Appendix X1. 1.5 A variety of solders are available that will produce sound, leak-tight joints. Choice of solder will depend upon the type of application and on local codes. For potable water systems, only lead-free solders shall be used, some of which are described in Specification B 32. 1.6 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information purposes only. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For hazard statements, see the warning statements in 6.4.1, 6.6.1, and 6.6.3.