本標準規定了便攜式鋰離子電池用鋁殼的要求、試驗方法、檢驗規則、標志、包裝、運輸、貯存、質量證明書和合同(或訂貨單)內容。本標準適用于各種便攜式鋰離子電池用鋁殼。
1.1 These requirements cover self-contained drinking-water coolers which employ hermetic refrigerantmotor-compressors and which are designed for connection to alternating-current circuits rated not greaterthan 600 volts in accordance with the National Electrical Code, NFPA 70. The requirements also apply towater coolers which supply both hot and cold water.1.2 These requirements do not include additional requirements applicable to equipment designed for usein hazardous locations as defined in the National Electrical Code, NFPA 70.1.3 A product that contains features, characteristics, components, materials, or systems new or differentfrom those covered by the requirements in this standard, and that involves a risk of fire, electric shock, orinjury to persons shall be evaluated using the appropriate additional component and end-productrequirements as determined necessary to maintain the acceptable level of safety as originally anticipatedby the intent of this standard. A product whose features, characteristics, components, materials, orsystems conflict with specific requirements or provisions of this standard cannot be judged to comply withthis standard. Where considered appropriate, revision of requirements shall be proposed and adopted inconformance with the methods employed for development, revision, and implementation of this standard.
1.1 This Outline of Investigation covers Modular Data Centers (MDC). The Modular Data Centers coveredby these requirements are pre-fabricated units consisting of an outer enclosure housing ITE and varioussupport equipment such as electrical service and distribution equipment, HVAC systems and the like.Some configurations may have the support equipment housed in a separate enclosure. A typicalconstruction may use a standard ISO shipping container or other structure as the outer enclosure, racksor cabinets of ITE, NEC compliant service entrance equipment and power distribution components, powerstorage such as a UPS and an air or liquid cooling system.1.2 These factory-built modules incorporate pre-installed materials and equipment which, afterinstallation, may be concealed and may not be accessible for inspection at the final installation site.1.3 The modular data centers covered by these requirements are intended for fixed installation eitherindoors or outdoors based on their construction and resistance to environmental conditions. MDCsintended for outdoor use shall be identified with a NEMA environmental class rating.1.4 These requirements are intended to demonstrate compliance with the National Electrical Code (NEC),NFPA 70 and other national Codes such as Building, Fire, Plumbing, Mechanical, and the like. Wherestate or local codes differ from the national codes anticipated by these requirements, determiningcompliance with these codes is the responsibility of the local authority having jurisdiction.1.5 When these requirements do not cover a specific technology or construction feature, the applicablerequirements of the National Codes shall be used.1.6 This Outline of Investigation assumes that the final installation of the MDC will be performed byqualified service personnel in accordance with the applicable installation instructions, installation practicesand national installation codes. These MDCs are intended for installation subject to approval by theAuthority Having Jurisdiction.
前沿科學
微信公眾號
中析研究所
抖音
中析研究所
微信公眾號
中析研究所
快手
中析研究所
微視頻
中析研究所
小紅書